SFP-2880の膜流量: 3.1 - 9.3 m3 /hr SFP-2880膜領域: 77m²
SFP-2880 膜公称孔径: 0.03 µm 核膜材料: PVDF
SFP-2880 濾液フラックス: 40-120 SFP-2880の直径: 8インチ
フロー方向設定: 外部圧力構造、行き止まりのろ過 SFP-2880最大TMPの動作: 2.1バー
最大入口モジュール圧: 6.25バー メムランの動作pH: 2-11
フロー構成: 外側、行き止まりの流れ 主要な認定: ISO 9001、NSF、CE
中心の適用: 飲料水および高品質の水の用途 このモジュールの利点: 非常に高い孔隙度,大きな流量

製品の説明

Dupont PVDF Ultrafiltration Membrane Model SFP-2880 For Drinking Water And High-quality Water Applications.

Why More Industrial Plants Choose DuPont UF Before RO
From process water to cooling and boiler makeup, DuPont ultrafiltration membranes help stabilize RO performance and reduce long-term operating costs.

Dupont PVDF Ultrafiltration Membrane Model SFP-2880 For Drinking Water And High-quality Water Applications. 0

Features

The SFD2880 is a pressure-type PVDF ultrafiltration membrane model optimized for drinking water and high-quality water applications.

1. Membrane material: PVDF

2. Nominal pore size: approximately 0.03 μm

3. Effective membrane area per module: approximately 75–80 m² (slight variations may occur between different batches and versions)

4. Typical operating flux range: approximately 40–115 LMH

5. Primarily used for municipal drinking water, advanced reclaimed water treatment, and projects with high requirements for effluent stability.

6. This model emphasizes highly efficient removal of pathogens, colloids, and turbidity.

Dupont PVDF Ultrafiltration Membrane Model SFP-2880 For Drinking Water And High-quality Water Applications. 1


Product Specifications

Product Specifications
Weight Membrane area Module volume (empty/ water filled)
Model Type Part # m2 ft2 Liters Gallons Kg lbs
SFP-2880 Pretreatment 280934 77 829 39 10.3 61/100 135/220
SFD-2880

NSF/ANSI 61

Drinking water

324169 77 829 39 10.3 61/100 135/220

Figure 1: SFP and SFD 2880 (8-inch diameter)


Operating Parameters


SI units US units
Filtrate Flux @ 25ºC 40-120 l/m2/ hr 24-70 gfd
Flow range 3.1-9.3 m3/hr 13.6 40.9 gpm
Temperature 1-40ºC 34-104ºF
Max. inlet module pressure (@ 20ºC) 6.25 bar 93.75 psi
Max. operating TMP 2.1 bar 30 psi
Max operating air scour flow 12 nm3/hr 7.1 scfm
Max backwash pressure 2.5 bar 36 psi
Operating pH 2- 11
NaOCl (max.) 2,000 mg/L
TSS (max.) 100 mg/L
Turbidity (max.) 300 ntu
Particle size (max.) 300 µ
Flow configuration Outside in, dead end flow
Expected filtrate turbidity ≤0.1 NTU
Expected filtrate SDI ≤2.5

Ensuring that the UF system is properly started is critical to preparing the membrane for operation and preventing potential membrane damage. Following the correct startup sequence is essential to maintaining system parameters within design specifications, helping to achieve water quality and productivity goals.

Before beginning the startup procedure, membrane preconditioning, membrane module installation, instrumentation calibration, and system checks must be completed per the guidelines outlined in the product technical manual.

To prevent membrane damage, sudden pressure changes during startup, shutdown, cleaning, or other sequences should be avoided. Before startup, flush the UF system thoroughly to eliminate any remaining shipping solution. In addition, purge any residual air from the system before commencing operation.

Start the unit manually, with the goal of achieving an initial permeate flow rate of 60% of the design capacity. Depending on the application, it may be necessary to discard the permeate obtained during initial operation. Refer to the product technical manual for detailed instructions.


General information

If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty (Form No. 795-00027) will be null and void.

To prevent biological growth during system shutdowns, it is recommended that preservative solution be injected into the membrane modules.

Regulatory note NSF/ANSI 61 certified drinking water modules require specific conditioning procedures prior to producing potable water. Please refer to the product technical manual flushing section for specific procedures. Drinking water modules may be subjected to additional regulatory restrictions in some countries. Please check local regulatory guidelines and application status before use and sale.

MODULE INSTALLATION


For application cases, please click:https://www.fgwater.com/Industries/

About Us

FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.


HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.

Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.

OUR CLIENTS

Dupont PVDF Ultrafiltration Membrane Model SFP-2880 For Drinking Water And High-quality Water Applications. 2

PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.

Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.

この製品の詳細を知りたい
に興味があります Dupont PVDF Ultrafiltration Membrane Model SFP-2880 For Drinking Water And High-quality Water Applications. タイプ、サイズ、数量、素材などの詳細を送っていただけませんか。
ありがとう!
お返事を待って。